Search

Catalogue (Export)

stack_catalogues

Contact Details

Company Profile

QR Code

contact

INstruchemie BV

Zwet 26

9932AB Delfzijl

The Netherlands

Tel: +31 596 634 831

Fax: +31 596 634 755

info@instruchemie.nl

 Chamber of Commerce

32044409

 

dialab

 

Bile Acids, Enzymatic Recycling

 

Liquid Reagents – ready to use

Bile Acids

Enzymatic Recycling

2 Reagents

dialab-kits

 

Diagnostic reagent for quantitative in vitro determination of total bile acid in human serum or plasma on photometric systems

REF

Cont.

 

903115

5 x 50 ml

4 x 45 ml Reagent 1

 

 

1 x 60 ml Reagent 2

903120

5 x 25 ml

4 x 22.5 ml Reagent 1

 

 

1 x 30 ml Reagent 2

903210

1 x 3 ml

Bile Acid Standard

903310

5 x 3 ml

Bile Acid Control

 

 

TEST PARAMETERS

Method:

Colorimetric, 2 Point Kinetic (fixed time),

 

Increasing Reaction, Enzymatic Recycling

Wavelength

405/600 nm

Temperature:

37°C

Sample:

Serum, EDTA plasma

Linearity:

up to 180 ?mol/l

Sensitivity:

The lower limit of linearity is 1 ?mol/l

 

Lithium, Enzymatic Recycling

Liquid Reagents – ready to us

Lithium

Enzymatic Recycling

2 Reagents

 

Diagnostic reagent for quantitative in vitro determination of lithium acid in human serum on photometric systems

REF

Cont.

 

9010210

3 x 20 ml

2 x 20 ml Reagent 1

 

 

2 x 10 ml Reagent 2

910280

3 x 3 ml

Lithium Standard Set (3 levels)

901290

2 x 3 ml

Lithium Control Set (2 levels)

 

 

TEST PARAMETERS

Method:

Enzymatic, 2 Point Kinetic (fixed time)

Wavelength

550 nm

Temperature:

37°C

Sample:

Serum

Linearity:

0.19 – 3.0 mmol/l

 

Sodium, Enzymatic Recycling

Liquid Reagents – ready to us

Lithium

Enzymatic Recycling

2 Reagents

 

Diagnostic reagent for quantitative in vitro determination of sodium in human serum on photometric systems

REF

Cont.

 

9091610

3 x 20 ml

2 x 20 ml Reagent 1

 

 

2 x 10 ml Reagent 2

909680

2 x 3 ml

Sodium Standard Set ( 2 levels)

 

 

TEST PARAMETERS

Method:

Enzymatic, 2 Point Kinetic (fixed time)

Wavelength

405 nm

Temperature:

37°C

Sample:

Serum

Linearity:

80 – 180 mmol/l

 

Potassium, Enzymatic Recycling

Liquid Reagents – ready to us

Potassium

Enzymatic Recycling

2 Reagents

 

Diagnostic reagent for quantitative in vitro determination of Potassium in human serum on photometric systems

REF

Cont.

 

910110

5 x 20 ml

4 x 20 ml Reagent 1

 

 

1 x 10 ml Reagent 2

909680

2 x 3 ml

Potassium Standard Set ( 2 levels)

909690

2 x 3 ml

Potassium Standard Set ( 2 levels)

 

 

TEST PARAMETERS

Method:

Enzymatic, 2 Point Kinetic (fixed time)

Wavelength

380 nm (380 – 405 nm)

Temperature:

37°C

Sample:

Serum

Linearity:

2 – 8 mmol/l