Search

Catalogue (Export)

stack_catalogues

Contact Details

Company Profile

QR Code

contact

INstruchemie BV

Zwet 26

9932AB Delfzijl

The Netherlands

Tel: +31 596 634 831

Fax: +31 596 634 755

info@instruchemie.nl

 Chamber of Commerce

32044409

 

biochemical_diagnostics

 

Welcome to Biochemical Diagnostics

For more than 25 years - Dedicated to keeping you at the "cutting edge" of Drugs of Abuse testing by providing you with state-of-the-art control material, SPE devices, reagents, hardware and... personal service to match.

bd-vacuumchamber

 

 

Biochemical Diagnostics

Detectabuse liquid Urine controls

 

The DETECTABUSE™ Advantage:

Detectabuse™ Series X-H & Confirm 2 controls are designed to monitor the performance of qualitative or quantitative procedures for the detection of drugs in urine. We also offer a complete line of controls for other immunoassay, hand held single use devices, GC/MS and custom formulations.

- Human urine-based matrix simulates patient samples

- Up to 12 drug constituents within one control

- Stable for up to 3 years frozen, or refrigerated (unopened)

- Series X-H in ready to use 20 mL vial size.

- Confirm 2 in ready to use 50 mL vial size.

- Each Series X-H control contains: THC,  Benzoylecgonine, PCP, Morphine, 6-MAM, d-Methamphetamine, MDMA, Secobarbital,             Oxazepam, Methadone, Methaqualone,         Propoxyphene

- Each Confirm 2 control contains: THC,             Benzoylecgonine (COC), PCP, Codeine,             Morphine (OPI), 6-MAM, d-Amphetamine d-            Methamphetamine, MDMA, MDA, MDEA

 

bd-bottles

 

 

 

NEW! DETECTABUSE™ LIQUID CONTROL URINE

IMMUNOASSAY SERIES X-H AND GC/MS CONFIRM 2

 

Catalog #

Series X-H (High Opiate, 2000 ng/mL Cutoff)

Vial Size

19601052

Series X-H Cutoff -25%

20 mL

19601056

Series X-H Cutoff +25%

20 mL

19601908

Series X-H 3X Cutoff (special Order Only)

20 mL

GC/MS Confirm 2

(High Opiate, 2000 ng/mL Cutoff)

 

 

19582001

Confirm 2 Cutoff -60%

50 mL

19582501

Confirm 2 Cutoff +25%

50 mL

 

bd-flyers

 

 

 

 

 

 

 

 

 

STEROID-SKREEN/VMA-SKREEN

As problems of radioactive waste disposal and environmental impact take on greater urgency, use of radioisotopes in clinical assays is becoming less acceptable.

It is not surprising, therefore, that the search for suitable alternatives has resulted in a reevaluation of colorimetric techniques that previously had been abandoned in favor of radioimmunoassays.

Recent advances in technology now allow these basic color reactions to be used at their full potential with interfering substances removed chromatographically by modern, easy-to-use disposable columns.

Each procedure is designed with one thing in mind, to allow a rapid, quantitative distinction between normal and abnormal values. By minimizing time and effort while maximizing accuracy and reliability Biochemical Diagnostics test kits provide a cost effective approach that both patients and physicians will appreciate.

Important Features:

No hydrolysis in the 17-OH Corticosteroid procedure.
The Amberlite resin extracts both free and conjugated steroids.

No Sample Drydown or Centrifugation.
Column extraction eliminates the need for centrifugation
and sample drydown; Zimmermann, Porter-Silber, and VMA-Diazo
Color Reactions are carried out directly in the column eluates.

No Glucose interference.
An important advantage in testing high risk pregnant diabetic
patients is the elimination of glucose interference. Glucose is
washed off the column prior to colorimetric analysis.

High Specificity.
With an almost total absence of in-vitro interfering substances,
these kits offer a degree of specificity not usually found with tests
of this type. There is no known dietary interference with the
VMA-Skreen test.

 

Test reproducibility is excellent

 

TEST

STANDARD
DEVIATION

COEFFICIENT
OF VARIATION

17-Ketosteroids

0.60

3.1%

17-Ketogenic Steroids

0.62

5.7%

17-OH Corticosteroids

0.30

6.5%

VMA (4-OH, 3-Methoxy-
mandelic Acid

0.28

7.0%

 

 

 

 

A PARTIAL LIST OF STEROIDS AND METABOLITES THAT CAN BE EXTRACTED USING DETECTABUSEtm OR MULTI-PREP® COLUMNS

ANABOLIC STEROIDS

 

STEROID METABOLITES

 

Extraction Procedure:

Extraction Procedure:

11-B-OH-Androsterone

 

11-B-OH-Etiocholanolone

 

5a-Androstandione

 

Androstendione

 

Bolasterone

 

Boldenone

 

cis-Androsterone

 

Clostebol

4-Chloro-3e-hydroxy-5e-androstan-17-one

D2-Testosterone

 

Dromostanolone

3e-hydroxy-2a-methyl-5a-androstan-17-one

Etiocholanolone

 

Fluoxymesterone

6-OH-Fluoxymesterone

Formyldienolone

17a-Methylandrosta-1,4-diene-2-hydroxymethylene-11a,17B-diol-3-one

Mesterolone

3e-Hydroxy-1a-methyl-5a-androstan-17-one

Methandienone

6-OH-Methandienone

Methenolone

3e-hydroxy-1-methylene-5a-androstan-17-one

Methyltestosterone

5e-Tetrahydromethyltestosterone

Nandrolone

cis-Norandrosterone
Noretiocholanolone

Norethandrolone

5e-Tetrahydronorethandrolone
Norpregnantriol

Oral-turinabol

6-OH-Oral turinabol

Oxandrolone

 

Oxymesterone

 

Oxymethalone

3e-6e-17B-Tri-hydroxy-2-hydroxymethyl-17a-methylandrostane

Stanozolol

3'-OH-epistanozolol  (3'-OH-Stanozolol)

Testosterone

 

 

 

 

A PARTIAL LIST OF DRUGS AND THAT CAN BE EXTRACTED USING DETECTABUSEtm OR MULTI-PREP® COLUMNS


 

Amphetamines

6-Monoacetylmorphine

Benzoylecgonine

Nicotine

Barbiturates

Nor-Propoxyphene

Benzodiazepines

Opiates

Caffeine

Extended Opiates

Cocaine and Metabolites

Orinase

Cotinine &Nicotine

Phenacetin

Cyclosporin

Phencyclidine

Dilantin

Phenylpropanolamine

Doriden and Metabolite

Placidyl and Metabolite

Elavil and Metabolites

Propoxyphene

Gabapentin (Neurontin)

Psylocin

Gamma-hydroxybutyrate (GHB)

Quinine and Metabolites

Ketamine

Ritalinic Acid and Metabolites

Long Acting Methadone(LAAM)

Scopolamine

Lysergic Acid and Metabolites

Talwin (Pentazocine)

Melleril Metabolites

Tetrahydrocannabinol and metabolites

Meprobamate

Thorazine and Metabolites

Methadone & EDDP Metabolite

Tricyclics

Methaqualone

 

Methylpyriline

 

 

 

NON-DRUG ANALYTES

 

Homocysteine

 

Methylmalonic Acid

 

Vitamin D2,D3